When First-Token Readouts Misread Feature Steering in a Medical Vision–Language Model

A first-token score can miss most of an intervention's effect on the answer a model writes.

Kevin Jin · Duke University

The Third Workshop on GenAI for Health · NeurIPS 2026

Paper Code Transcoder weights BibTeX

Summary

To find out what an AI model relies on, researchers turn parts of it down and watch what changes. On yes/no questions, that change is usually scored from the first word the model would write. In a medical model that reads chest X-rays, we show that this score can miss most of the change in the answers the model actually writes.

In interpretability terms, the score is Pnorm, the probability of “yes” normalized over “yes” and “no”: the probability form of the logit difference recommended for activation patching.

How it works

  1. Step 1 · Ask

    We show MedGemma 1.5 (4B), Google's open medical vision–language model, a chest X-ray and ask: “Does this chest X-ray show cardiomegaly? Answer yes or no.” Cardiomegaly is an enlarged heart. We use 40 X-rays that the model calls enlarged although their labels say they are not.

  2. Step 2 · Find features

    A transcoder is a second network, trained to rewrite what each layer of the model computes as a sparse set of features that can be read and edited one at a time. Ours covers all 34 layers, with 2,048 features per layer. On each X-ray we take the 80 features most active on the image.

  3. Step 3 · Turn them down

    We reverse or zero those 80 features while the model reads the image, applying the edit the way circuit-tracing tools do. Every comparison is between the same model with and without the edit.

  4. Step 4 · Score it two ways

    The usual score reads only the first word the model would write: the probability of “Yes” as a share of “Yes” plus “No”, Pnorm. We also let the model write 50 full answers per X-ray and count the share that say yes, s.

Key findings

1

The answers move; the score barely does

Turning the features down (scale −1) barely moves the first-token score Pnorm. The share of written answers that say yes falls much further.

0.976→0.933
first-token score, Pnorm
0.95→0.73
share of answers that say yes, s
What the first token says, and what the model then writes
MedGemma 1.5 (4B), 40 cardiomegaly false positives, 50 sampled answers each
  • yes
  • yes, after reasoning
  • other first token · neither answer
  • no, after reasoning
  • no
Figure 1. Upper bar: the probability of the first output token. Lower bar: what 50 sampled answers conclude, and whether they answer directly (dark) or after reasoning (light). Suppression moves the first token from “yes” to reasoning, and the reasoning now often ends in “no”; Pnorm, the “yes” share of “yes” plus “no”, misses both. Covering the evidence also moves the first token to “no”, so Pnorm falls with the answers. Hover a segment for its value.
2

It misses 88% of the answers the edit flips

Over three suppression variants, the edit turns 32 of 120 greedy answers to “no”, and Pnorm still says yes on 28 of them. When we cover the evidence in the image instead, the first token becomes “No” too, and the score misses only 3 of 53.

Film by film: the score against the written answers
Each point is one of the 40 films under one intervention
  • greedy answer yes
  • greedy answer no
  • neither
Figure 2. The sampled yes rate s against Pnorm after the edit. A red square above the dashed line is an answer the edit turned to “no” on which the score still says yes. Hover a point for its values.
3

The model reasons its way to “no”

After suppression the model more often opens with “Based on the image” instead of “Yes”, and that reasoning more often ends in “No”. Its first token almost never becomes “No”, so a score read there sees no change.

Unedited
Yes, the chest X-ray shows cardiomegaly. The heart appears enlarged.
After suppressionPnorm = 0.982
Based on the image, the chest X-ray shows a normal heart size. Therefore, the answer is **No**.
4

It holds beyond one setup

The gap replicates on radiographs selected by their written answer alone and on correct effusion and pneumothorax calls. We hypothesize that it comes from how circuit-tracing tools apply edits, which constrain the first token but not the rest of the answer.

Takeaway. An edit that looks inert by this score can still change what the model tells a clinician. Score interventions on sampled answers, and report first-token readouts alongside them.

Code and weights

The training checkpoint is also archived on Zenodo, 10.5281/zenodo.22105454.

Citation

@inproceedings{jin2026firsttoken,
  title     = {When First-Token Readouts Misread Feature
               Steering in a Medical Vision--Language Model},
  author    = {Jin, Kevin},
  booktitle = {The Third Workshop on GenAI for Health: Agentic
               Systems, Clinical Trust, and Future Potential
               (NeurIPS 2026 Workshop)},
  year      = {2026}
}